<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-24T08:07:21Z</responseDate><request verb="GetRecord" identifier="oai:www.repository.cam.ac.uk:1810/322398" metadataPrefix="uketd_dc">https://api.repository.cam.ac.uk/server/oai/request</request><GetRecord><record><header><identifier>oai:www.repository.cam.ac.uk:1810/322398</identifier><datestamp>2024-06-26T13:54:27Z</datestamp><setSpec>com_1810_213729</setSpec><setSpec>com_1810_256065</setSpec><setSpec>col_1810_219485</setSpec></header><metadata><uketd_dc:uketddc xmlns:uketd_dc="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:uketdterms="http://naca.central.cranfield.ac.uk/ethos-oai/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/ http://naca.central.cranfield.ac.uk/ethos-oai/2.0/uketd_dc.xsd">
   <dc:title>In-liquid bulk acoustic wave resonators for biosensing applications</dc:title>
   <dc:identifier xsi:type="dcterms:DOI">10.17863/CAM.69855</dc:identifier>
   <dc:creator>Rughoobur, Girish</dc:creator>
   <uketdterms:advisor>Flewitt, Andrew</uketdterms:advisor>
   <dcterms:abstract>Gravimetric sensors based on thin-film bulk acoustic wave (BAW) resonators operating between 1-5 GHz have tremendous potential as biosensors because they are inexpensive, label-free, fast and highly sensitive. The two main challenges in this objective are: the conventional longitudinal mode resonance in $\textit{c}$-axis oriented piezoelectric films suffers from more than 90% damping in liquid; the alternative is the shear mode resonance, with lower damping in liquid but which requires an inclined $\textit{c}$-axis piezoelectric film, a process that is still not fully scalable. In this thesis, seed layers such as AlN with mainly (103) orientations are used to promote the growth of homogeneously inclined $\textit{c}$-axis ZnO (inclination of up to $\sim$45$^{\circ}$) films without significant equipment modifications. Sputtered Al electrodes with controlled roughness are then substituted for the parasitic AlN seed layers to improve the electromechanical performance. At a substrate temperature, T$_{s}$ = 100 $^{\circ}$C, an optimum surface roughness of 9.2 nm yields homogeneously inclined $\textit{c}$-axis ZnO films with angles $\sim$25$^{\circ}$. Solidly mounted resonators (SMRs) operating in a shear mode at $\sim$1.1 GHz with the Al electrodes have resonant quality factors (Q$_{r}$) higher than 150 and effective electromechanical coupling coefficients, k$^{2}$$_{eff}$, of 2.9-3.4%, which are improved from only 2.2% with the AlN seed layers. This shear mode of the ZnO SMRs has mass sensitivities, S$_{m}$ of (4.9 $\pm$ 0:1) kHz$\cdot$cm$^{2}$/ng and temperature coefficients of frequency (TCF) of -(66$\pm$2) ppm/K. Viscosity sensing is carried out with different ethanol-water compositions; the SMRs are functionalised and successfully used in the detection of Rabbit Immunoglobin G. To mitigate the longitudinal mode damping in water, multi-wall carbon nanotube (CNT) forests are grown by chemical vapour deposition (CVD) at 600 $^{\circ}$C using Fe/Al layers on the active area of inclined $\textit{c}$-axis AlN SMRs designed for improved thermal and chemical stability. The dense CNT forest (with 0.5/8 nm Fe/Al) of $\sim$15 μm height provides an acoustic isolation to DI water with only 50-70% drop in the longitudinal mode Q$_{r}$ compared to 99% in SMRs without the CNTs. Mass loading is still detected and demonstrated by detecting bovine serum albumin (BSA) in water whereas with forest heights of $\sim$30 μm and no significant frequency shifts due to mass attachment are observed. With the CNTs the longitudinal mode is shown for the first time to be more sensitive to mass ($\sim$7x) than the shear mode in liquid, highlighting the potential of CNTs for the large scale use of the longitudinal mode for in-liquid sensing.</dcterms:abstract>
   <uketdterms:institution>University of Cambridge</uketdterms:institution>
   <dcterms:issued>2017-01-16</dcterms:issued>
   <dc:type>Thesis</dc:type>
   <uketdterms:qualificationlevel>doctoral</uketdterms:qualificationlevel>
   <uketdterms:qualificationname>PhD</uketdterms:qualificationname>
   <dc:language>en</dc:language>
   <dcterms:isReferencedBy xsi:type="dcterms:URI">https://www.repository.cam.ac.uk/handle/1810/322398</dcterms:isReferencedBy>
   <dc:identifier xsi:type="dcterms:URI">https://apollo8-f-pro.lib.cam.ac.uk/bitstreams/14477a15-2c83-4944-af2d-10b9f0a5b3fe/download</dc:identifier>
   <uketdterms:checksum xsi:type="uketdterms:MD5">54cdef7a528d94e330d2bb156825b164</uketdterms:checksum>
   <dcterms:license>https://apollo8-f-pro.lib.cam.ac.uk/bitstreams/d7ce1fc2-532a-4146-a35a-8a8dbdf6f555/download</dcterms:license>
   <uketdterms:checksum xsi:type="uketdterms:MD5">87eda9de84448d1f82354d60eee3eb5f</uketdterms:checksum>
   <dc:rights>https://www.rioxx.net/licenses/all-rights-reserved/</dc:rights>
   <dc:subject>Bulk acoustic wave resonators</dc:subject>
   <dc:subject>Biosensors</dc:subject>
   <dc:subject>Gravimetric sensors</dc:subject>
</uketd_dc:uketddc>
</metadata></record></GetRecord></OAI-PMH>